CyberResearch RS-485 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Netzteile CyberResearch RS-485 herunter. CyberResearch RS-485 User`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 30
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Serial Communications
USER’S MANUAL
VER. 1.0 • DEC 2003
No part of this manual may be reproduced without permission
COML 106U-D25
Low Profile Universal PCI-Bus 1-Port RS-232/422/485/530
Serial Interface Card, 460.0 kbps Data Rate, 128-Byte
FIFO Buffer, with DB-25M Connector (for 3.3V or 5V slot
)
COML 106U-X-D25
Low Profile Universal PCI 1-Port RS-232/422/485/530
Serial Interface Card, 460.0 kbps Data Rate, 128-Byte
FIFO Buffer, with DB-25M Connector and Isochronus
Communications (for 3.3V or 5V slot)
®
CyberResearch
®
, Inc.
www.cyberresearch.com
25 Business Park Dr., Branford, CT 06405 USA
203-483-8815 (9am to 5pm EST) FAX: 203-483-9024
Seitenansicht 0
1 2 3 4 5 6 ... 29 30

Inhaltsverzeichnis

Seite 1

Serial CommunicationsUSER’S MANUAL VER. 1.0 • DEC 2003 No part of this manual may be reproduced without permission COML 106U-D25 Low Profile Universal

Seite 2

ATRTDTOPNEFigure 5 – Header E5, RS-485 ‘RTS’ Enabled, with ‘Echo’ATRTDTOPNEFigure 6 – Header E5, RS-485 ‘DTR’ Enabled, with No EchoAddress and IRQ sel

Seite 3 - CyberResearch, Inc. iii

Figure 7 - Header E4, Line TerminationElectrical Interface Selection Each port on the COML 106U has the ability to be used in either RS-232 or RS-422/

Seite 4

Clock ModesThe COML 106U employs a unique clocking option that allows the end user to select from divide by 8 and divide by 1 clocking modes. These mo

Seite 5 - Contents

Baud Rates and Divisors for the ‘Div1’ mode The following table shows some common data rates and the rates you should choose to match them if using th

Seite 6

InstallationOperating System Installation Windows 95/98/ME/NT/2000/XP Do not install the Adapter in the machine until the software has been fully inst

Seite 7 - Introduction

Physical Installation The adapter can be installed in any 5V PCI expansion slot and contains several jumper straps for each port that must be set for

Seite 8 - Card Setup

Technical Description The CyberResearch, Inc. COML 106U provides a PCI interface adapter with an additional asynchronous serial port providing a versa

Seite 9

RS-422/485/530 Pin Assignments (DB25 Male) Signal Name Pin # Mode GND Ground 7 RDB RX+ Receive Positive 16 Input RDA RX- Receive Negati

Seite 10 - Line Termination

SpecificationsEnvironmental Specifications Specification Operating StorageTemperatureRange0º to 70º C (32º to 158º F) -50º to 105º C(-58º to 221º F) H

Seite 11

Appendix A - TroubleshootingThe software is supplied with the CyberResearch, Inc. adapter and may be used in the troubleshooting procedures.Using this

Seite 13 - Isochronous Clocking Jumpers

Appendix B - Electrical Interface RS-232Quite possibly the most widely used communication standard is RS-232. This implementation has been defined and

Seite 14 - Installation

Appendix C - Asynchronous Communications Serial data communications implies that individual bits of a character are transmitted consecutively to a rec

Seite 16 - Technical Description

Appendix E - Compliance Notices Federal Communications Commission Statement FCC - This equipment has been tested and found to comply with the limits f

Seite 17

COML 106U(-X)-D25 CyberResearch®Serial Communications iv ©Copyright 2003, CyberResearch, Inc.Intentionally Blank

Seite 18 - Specifications

CyberResearch®Serial Communications COML 106U(-X)-D25 CyberResearch, Inc. 1925 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford

Seite 19 - Appendix A - Troubleshooting

COML 106U(-X)-D25 CyberResearch®Serial Communications 20 ©Copyright 2003, CyberResearch, Inc.Intentionally Blank

Seite 20

CyberResearch®Serial Communications COML 106U(-X)-D25 CyberResearch, Inc. 2125 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford

Seite 21 - 5 to 8 Data Bits

COML 106U(-X)-D25 CyberResearch®Serial Communications 22 ©Copyright 2003, CyberResearch, Inc.Intentionally Blank

Seite 23 - EMC Directive Statement

CyberResearch®Serial Communications COML 106U(-X)-D25 CyberResearch, Inc. iii25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branfor

Seite 24 - Intentionally Blank

CyberResearch, Inc.25 Business Park DriveBranford, CT 06405 USAP: (203) 483-8815; F: (203) 483-9024www.cyberresearch.com

Seite 25 - Diagnosis and Debug

COML 106U(-X)-D25 CyberResearch®Serial Communications iv ©Copyright 2003, CyberResearch, Inc.Intentionally Blank

Seite 26

ContentsIntroduction... 1OVER

Seite 27 - Warranty Notice

Appendix E - Compliance Notices ... 18FEDERAL COMMUNICATIONS COMMIS

Seite 28

IntroductionOverviewThe CyberResearch, Inc. COML 106U is a one channel PCI Bus serial I/O adapter for the PC and compatibles. It provides one field se

Seite 29

Card Setup RS-485 Enable Modes RS-485 is ideal for multi-drop or network environments. RS-485 requires a tri-state driver that will allow the electric

Seite 30 - CyberResearch, Inc

RS-485 Mode Examples (Header E5) ATRTDTOPNEFigure 1- Header E5, RS-422 ATRTDTOPNEFigure 2 – Header E5, RS-485 ‘Auto’ Enabled, with ‘No Echo’ ATRTDTOPN

Kommentare zu diesen Handbüchern

Keine Kommentare